• Deutsch
  • Español
  • Nederlands
  • Dansk
  • Suomi
  • Norsk
  • Svenska
  • Italiano

FD16 FDQ16 : 16mm Bores 12.5-50Nm

Couplings » Flexible Drive Shafts »
FD16 & FDQ16 Type : 16mm bores - 12.50Nm-50.00Nm

FD16 FDQ16 Masterflex Flexible Drive Shaft with Oilite Bushes or Ball Bearings
FD16 FDQ16 Masterflex Flexible Drive Shaft with Oilite Bushes or Ball Bearings Diagram

Discounts 1+ 0% 5+ 5% 25+ 10%

Part
Number
Bore

Direction

Max
Speed
Rpm

Shaft
Length

Bearings/
Bushes

Cost Quantity Add to
Basket
FD16500 Ø15 A 4000 500 Ball
Bearings
£303.75
B 2000 £303.75
C 4000 £303.75
FDQ16500 Ø15 A 2000 500 Oilite
Bushes
£254.59
B 200 £254.59
C 2000 £254.59
FD161000 Ø15 A 4000 1000 Ball
Bearings
£366.18
B 2000 £366.18
C 4000 £366.18
FDQ161000 Ø15 A 2000 1000 Oilite
Bushes
£317.04
B 200 £317.04
C 2000 £317.04
FD161500 Ø15 A 4000 1500 Ball
Bearings
£428.58
B 2000 £428.58
C 4000 £428.58
FDQ161500 Ø15 A 2000 1500 Oilite
Bushes
£379.46
B 200 £379.46
C 2000 £379.46
FD162000 Ø15 A 4000 2000 Ball
Bearings
£491.06
B 2000 £491.06
C 4000 £491.06
FDQ162000 Ø15 A 2000 2000 Oilite
Bushes
£441.90
B 200 £441.90
C 2000 £441.90
FD162500 Ø15 A 4000 2500 Ball
Bearings
£559.93
B 2000 £559.93
C 4000 £559.93
FDQ162500 Ø15 A 2000 2500 Oilite
Bushes
£504.89
B 200 £504.89
C 2000 £504.89
FD163000 Ø15 A 4000 3000 Ball
Bearings
£615.89
B 2000 £559.93
C 4000 £559.93
FDQ163000 Ø15 A 2000 3000 Oilite
Bushes
£567.17
B 200 £567.17
C 2000 £567.17

A = Anti-clockwise rotation, B = Bi-direction rotation, C = Clockwise rotation (standard)

Direction

Min.
Operating
Radius

Torsional Deflection
(0.1Nm Load at 1m Length

Max Torque (Nm) v Bend radius (mm)

Wind Unwind

300mm

350mm

500mm

600mm

800mm

1000mm

A & C
300
0.27°
0.23°
12.50Nm
14.00Nm
16.00Nm
18.00Nm
20.00Nm
25.00Nm
B
300
0.06°
0.13°
20.00Nm
28.00Nm
35.00Nm
40.00Nm
45.00Nm
50.00Nm

Material
Shafts & Ends:
Steel 070M420 with plastic cover

End Type:
M = Supplied both ends as standard (FD Type - Ball Bearing)
R = Supplied both ends as standard (FDQ Type - Oilite Bush)
Please specify end option if required different.
Eg. MN, NN / RS, SS
The flexible core has a layer of grease for lubrication in operations of continuous usage eg. an 8 hour day.
We recommend you regrease and check the flexible centre every 3 months.
The knurled ends unscrew to allow the shaft to come out. Re-seal after inspection
Spare flexible centres can be purchased to replace broken or worn examples.

Downloads
PDF Icon PDF Documents : Catalogue Page | Technical | Full Range (inc. Technical)
Sign in, or register: Why register? | Forgot password?